23. General requirement regarding plot.

  1. No land development or redevelopment shall be made or no building shall be constructed on any plot on any part of which there is deposited refuse, excreta or other offensive matter which in the opinion of the Secretary is considered objectionable, until such refuse, excreta or other offensive matter has been removed there from and the plot has been prepared or left in a manner  suitable for land development or building purpose for the satisfaction of the Secretary.
  2. No land development or redevelopment shall be made or no building shall be constructed on a plot, which comprises or includes a pit, quarry or other similar excavation or any part thereof unless such plot has been prepared or left in a manner or condition suitable for land development or redevelopment or building purposes to the satisfaction of the Secretary.
  3. No land development or redevelopment shall be made or no building shall be constructed on a plot liable to flood or on a slop forming an angle of more than 45 degrees with horizontal or on soil unsuitable for percolation or on area shown as floodable area in any town planning scheme or in sandy beds, unless it is proved by the owner to the satisfaction of the Secretary that construction of such a building will not be dangerous or injurious to health and the site will not be subjected to flooding or erosion or cause undue expenditure of public funds for providing sewers, sanitation, water. supply or other public services.
  4. Any land development or redevelopment or building construction or reconstruction in any area notified by the Government of India as a coastal regulation zone under the Environment (Protection) Act, 1986 (29 of 1986) and rules made thereunder shall be subject to the restrictions contained in the said notification as amended from time to time.
  5. No building or part of a building shall be constructed or reconstructed or no addition or alteration shall be made to any existing building in the intervening spaces between the building and any overhead electric supply line as described in the Table 1 below and as specified in the Indian Electricity Rules as amended from time to time.
    Provided that single storied buildings shall be allowed even if the above mentioned clearance is not available, if the applicant produces a no objection certificate from the Chief Electrical Inspector or an officer authorized by him, before issue of permit
TABLE 1
Clearance from Overhead Electric Lines
Sl. No. Type of Electric Supply Line Vertical clearance in meters Horizontal clearance in meters
(1) (2) (3) (4)
1. Low and medium voltage lines 2.4 1.2
2. High voltage lines upto and including 33,000 volts 3.7 1.85
3. Extra high voltage lines excluding 33,000 volts 3.7
plus 0.3m fort every additional 33,000 volts or part thereof
1.85
plus 0.3m fort every additional 33,000 volts or part thereof