30. Conditions on which licence may be granted

  1. No licence shall be granted in respect of any building or enclosed place unless the provisions of sub-rules (2) to (5) of this rule are complied with.
  2. Such building or place shall have at least two main exits of not less than 2.4 metres in height and 1.75 metres in width. Where these exits are enclosed by doors, the door shall be so made as to open outwards. Such exits shall be so arranged that they can be pushed open easily and at once from inside.
  3. When the area of such building or enclosed place exceeds 100 sq. metres at least one additional special exit per 50 sq. metres of additional space shall be provided in the exterior walls of such building or place at suitable distances. Each of such special exits shall be not less than 2.4 metres in height and 1.75 metres in width. Such special exits may beclosed whilst such building orplace is being used as aplace of public resort
    but the means adopted for using them in cases of emergency shall be specified in the licence.
  4. Each of such exits shall be indicated by a board with the word "EXIT" clearly painted upon it in English and in Malayalam in large and legible letters.
  5. Sufficient provision shall be made for preventing and extinguishing fire which may occur in or upon such building or place and such provision shall be specified in column (9) of the licence, A supply of not less than 25 litres of water per iOsq. metres of area in the case of a permanent building or enclosed place shall be provided and kept stored in buckets in readiness along with the walls of such building or place. In thecase of temporary buildings, the supply of water shall be not less than 50 litres per 10 sq, metres of area and shall be stored in buckets in readiness, one half within and the other half without the exterior walls of the building :

    Provided that where any building or enclosed place by reason of its construction and disposition so requires, the licensing authority may grant for such building or place a licence with such modifications in regard to the storing of water and the disposal of the water stored, for combating fire, as may be deemed sufficient and suitable.